Test function requirements: Detect the service life of snap-action thermostats. The total number of tests can be set, and the system will automatically stop and provide an audible and visual alarm after the set number of tests is reached.

Keywords:

Product Description

Product Overview
  Test function requirements: Detect the service life of snap-action thermostats. The total number of tests can be set, and the test will automatically stop with audible and visual alarm prompts after the set number of tests is reached.
Equipment functions and configuration:
1) It adopts PLC and touch screen control, and the test function and parameters can be set and displayed on the display screen.
2) The test parameters have a power-off memory protection function.
3) The parameters set on the display screen and the test count have a password protection function to avoid accidental modification or loss of test parameters due to human error.
4) During the test, it automatically determines whether the thermostat operates normally within the heating, cooling, and reset times. If there is any abnormality, it automatically stops the test and provides audible and visual alarm prompts.
5) The test automatically stops after reaching the preset value, and audible and visual alarm prompts are given, displaying the words 'Test completed' on the display screen.
6) The thermostat is installed on a dedicated tooling fixture.
7) It has short-circuit, leakage, and overload protection devices.


Main Technical Parameters
(1) Working power supply: AC220V±10%, 50Hz;
(2) Test stations: six stations;
(3) Heat transfer medium: hot air (hot air is provided by 1 hot air gun);
(4) Cooling medium: air cooling;
(5) Test temperature: room temperature to 350℃;
(6) Qualified test times: 1~999999 times can be preset;
(7) Number of failed tests: 1~9999 times;
(8) Heating time: 1~9999 seconds can be set;
(9) Cooling time: 1~9999 seconds can be set;
(10) Reset method: forced air cooling;
(11) Simultaneous testing of six stations;
(12) Instrument specifications: 800 (width) * 1100 (length) * 1460mm (height).

 