Product Categories
ZJ-3500A
Comprehensive Test Bench for Circuit Breaker Trip Characteristics
Category:
Keywords:
Product Description
ZJ-3500A Circuit Breaker Trip Characteristic Comprehensive Test Bench
1. Product Overview:
This circuit breaker test bench is designed and manufactured according to the technical requirements provided by the customer, complying with national standards GB10963.1-2005 Article 9.10, GB14048.1-2006 Article 7.2.1, JB/T8979-2006 Article 8.13. It can perform delayed trip characteristic tests on circuit breakers by applying 1.13 times, 1.45 times, and 2.55 times the rated current to check if it trips within the specified time; it can also perform instantaneous trip characteristic tests by applying 3 to 10 times the rated current to check if it trips within the specified time. It is suitable for online factory testing of molded case circuit breakers and miniature circuit breakers and is essential equipment for circuit breaker manufacturers for electrical performance testing. This equipment features quick product installation, automatic testing, and automatic judgment functions. It offers multiple specifications of wire terminals (for delayed trip testing), reasonable design, ease of use, simple operation, reliable performance, and an attractive appearance.
2. Main Technical Parameters:
1 Input Power Supply: Three-phase 380V/50HZ/15KVA;
Molded Case Circuit Breaker Characteristics: Miniature/molded case instantaneous trip characteristics, delayed trip characteristics, temperature rise and power consumption testing.
Control Method: PLC touch screen (Siemens) control. Constant temperature chamber: This chamber is integrated with the test machine, capable of maintaining temperature from room temperature to 50°C, temperature resolution 0.1°C, temperature stability ±1°C (using terminal post method, delayed three stations, instantaneous one station; suitable for 1-4P circuit breakers).
2. Delayed Trip Parameters:
1) Output AC Current: 5~600A
2) Output AC Voltage: 0~5V;
3) Number of Output Current Channels: 3 channels
4) Test Range for Miniature Circuit Breaker Products: 5-125A
5) Test Range for Miniature Circuit Breaker Products: 63~250A
6) Current Output Waveform: Sine wave (calibrated device current waveform distortion not greater than 5%, system error not greater than 3%)
7) Current Control Method: Automatic adjustment, current set on touch screen;
8) Current Accuracy: Class 0.5;
9) Voltage Accuracy: Class 0.5;
10) Transformer Ratio: 600/5A;
11) Test Time: 999999 s
12) After applying 1.13 times current, quickly and automatically rise to 1.45 times current within 5 seconds;
13) Fixture: Using terminal post method, delayed three stations, instantaneous one station; suitable for 1-4P circuit breakers.
3. Instantaneous Trip Test Parameters:
1) Fixture: Using terminal post method,
2) Output Current: AC 60~3500A
3) Number of Output Current Channels: 1 channel,
4) Current Accuracy: Class 0.5;
5) Resolution: 1A
6) Instantaneous Test Time ≤ 0.2s;
7) Upper Limit Setting for Action Time: 1~200ms;
8) Lower Limit Setting for Action Time: 1~200ms;
9) Test Station: 1 station
10) Conduction Angle: 0~180 degrees selectable
11) Equipment Control Method: PLC + touch screen control
12) Timing Duration: 1~99999ms;
13) Protection Functions: Short circuit protection, overload protection, leakage protection;
14) Operating Environment Temperature: 0 ~ +40℃;
15) Relative Humidity: (20 ~ 90)%RH; Cabinet Dimensions: Length 1800 * Width 780 * Height 1600
4. Temperature Rise and Power Consumption Test:
Under normal working conditions, when the circuit breaker is tested according to specified conditions, the temperature rise of each component shall not exceed the limit value,
and the circuit breaker shall not be damaged in a way that affects its function or safety of use.
Temperature measurement: 8 channels, resolution 0.1°C;
Accuracy: Class 0.2, measurement and control speed 0.1 seconds per channel.
Wires for temperature rise test: 1, 1.5, 2, 0.5, 4, 6, 10 square millimeters, each specification length 1 meter, quantity 2 pieces;
Wires for temperature rise test: 16, 25, 50, 70, 95, 120 square millimeters, each specification length 2 meters, quantity 2 pieces;
Measurement range 0~200 degrees;
Thermocouple type: Type T
Features temperature curve display; includes temperature data recording table.
Previous Page:
Next:
Previous Page:
Durability Testing Device for Power Tools
Next Page:
Online Consultation
Get prices and free samples now!